Tracksense Pro wireless thermal validation

  • Ellab has incorporated the latest in electronic technology and innovation to deliver a wireless multi-channel data logger unmatched in accuracy, performance and versatility. The flexible system is easily adapted to your requirements and provides an elegant solution to the most demanding validation applications.
So Sánh

Mô tả

Tracksense Pro wireless thermal validation

Brand: Ellab – Denmark

Ellab-header

The ultimate solution in wireless thermal validationEllab has incorporated the latest in electronic technology and innovation to deliver a wireless multi-channel data logger unmatched in accuracy, performance and versatility. The flexible system is easily adapted to your requirements and provides an elegant solution to the most demanding validation applications.

TSP_reader_stations_L

Accuracy
The incorporation of state of the art technology and extensive testing have resulted in:

• Temperature: ±0.05°C
• Humidity: ±2%
• Pressure: ±0.25% Full Scale
• Time: ±5 Sec. Per 24 Hours
• Rotation: ±1%

Compare and you will find TrackSense® Pro the most accurate data logger available on the market today.

Alle_loggere_L

Performance
The robust loggers are designed to operate under extreme conditions without ever losing valuable data. They can tolerate temperatures from -80°C to +150°C and withstand pressures up to 10 Bar fully immersed. The non-volatile memory stores up to 60,000 data points. Recent improvements in battery technology have dramatically improved performance and lifetime even at high temperatures.

The small size and convenience of wireless data loggers make them exceptionally easy to use in countless validation applications.

TRACKSENSE® PRO TECHNICAL SPECIFICATIONS

Multi Reader Station
TSP_reader_4sensor_Large
 
Operating Temperature 5°C to 40°C/ 41°F to 104°F
Operating Voltage 5V External Adapter 100-240V AC, 50-60 Hz or USB
Reader/Logger Communication Induction
PC Interface USB
Capacity 1-4 Loggers at a Time
Expansion 1-3 Modules
Expansion Capacity 5-16 Loggers
Single Reader Station
Single-readerstation_L
 
Operating Temperature 5°C to 40°C/ 41°F to 104°F                               
Operating Voltage NA
Reader/Logger Communication Induction
PC Interface USB
Capacity 1 Logger at a Time

TSP Logger

logger-type-01

 
Logger Basic Pro Pro X Pro XL
Operating Temperature: -30 to +105°C

-50 to +150°C

-80 to +150°C

-80 to +150°C

Operating Pressure: *

0 mbar to 10 bar abs

0 mbar to 10 bar abs

0 mbar to 10 bar abs

0 mbar to 10 bar abs

Material:

316L Stainless Steel

316L Stainless Steel

316L Stainless Steel

316L Stainless Steel

Diameter:

25 mm.

25 mm.

25 mm.

25 mm.

Length:

44 mm.

44 mm.

44 mm.

68.8 mm.

Weight With Battery:

48 Grams

48 Grams

48 Grams

Memory Capacity:

60,000 Data Points

60,000 Data Points

60,000 Data Points

60,000 Data Points

Minimum Sample Rate:

1 Second

1 Second

1 Second

1 Second

Maximum Sample Rate: 24 Hours

24 Hours

24 Hours

24 Hours

Maximum Start Delay: 14 Days

14 Days

14 Days

14 Days

Intrinsically Safe: Ex II G 
EEx ia IIC T3
-30 to +105°C

Ex II G
EEx ia IIC T3
-50 to +105°C

Ex II G
EEx ia IIC T3
-60 to +105°C

Compliance: CE

CE

CE

CE

Sensor: Interchangeable

Interchangeable

Interchangeable

Interchangeable

Time Accuracy: ±5 Seconds 
Per 24 Hours

±5 Seconds
Per 24 Hours

±5 Seconds
Per 24 Hours

±5 Seconds
Per 24 Hours

Battery: TSP Standard Battery TSP Standard Battery TSP Standard Battery TSP 150L Battery
*In accordance with UL Certificate 06 ATEX 140022X, group 2, TrackSense® Pro, Pro X and Pro Basic loggers equipped  with pressure sensors and relative humidity sensors can not be exposed to more than 1.1 bar and 105°C when  working in an environment where intrinsically safe equipment is required. 
logger-range
logger-type-02
logger-type-3
 

Technical Specifications for rigid sensors

logger-img

 
Type

     Rigid SS Standard

      Rigid SS High
Diameter                 2 mm / 3 mm                       3 mm
Length                  From 10 mm                 From 150 mm 
Dimension of sensing element                 1.2 x 1.6 mm                  1.2 x 1.6 mm
Position of measuring point:    
From round tip                    3 mm                        3 mm
From sharp tip                    6 mm                        6 mm 
From conical tip                    8 mm                        8 mm
Temperature measuring range             -196°C to +150°C                    0 to +400°C
Accuracy:    
Low -196 to -80°C                   ± 0.5°C                         –
Low -80 to -50°C                   ± 0.3°C
Low -50 to -40°C                   ± 0.2°C
Low -40 to -25°C                   ± 0.1°C
Low -25 to 0°C                   ± 0.05°C
Standard 0 to 100 °C                   ± 0.05°C
Standard +100 to +140°C                   ± 0.05°C
Standard +140 to +150°C                           ± 0.05°C
High 0 to +400°C                         –                     ± 0.5°C
Sensor capacity 1 or 2       1
Sensor response time:    
T-10% 0.11 sec. / 0.22 sec.  
T-50% 0.35 sec. / 0.72 sec.  
T-63% 0.5 sec. / 1.00 sec.  
T-90% 1.10 sec. / 2.00 sec.  
Pressure operating range 0.001 mBar to 10 Bar ABS  0.001 mBar to 10 Bar ABS 

Technical Specifications for Stainless Steel sensors

 
Type Semi Flexible SS Standard Semi Flexible SS High
Diameter 1.5 mm / 2 mm / 3 mm  2.0 mm / 2.5 mm
Length 100 -1000 mm 150 – 1000 mm
Dimension of sensing element  0.8 x 3.0 mm / 1.2 x 1.6 mm / 1.2 x 1.6 mm  1.2 x 1.6 mm
Position of measuring point:    
From round tip 3 mm 3 mm
From sharp tip 6 mm 6 mm 
From conical tip 8 mm 8 mm
Temperature measuring range  -196°C to +150°C  0 to +400°C
Accuracy:    
Low -196 to -80°C  ± 0.5°C
Low -80 to -50°C ± 0.3°C
Low -50 to -40°C ± 0.2°C
Low -40 to -25°C ± 0.1°C
Low -25 to 0°C ± 0.1°C
Standard 0 to 100°C ± 0.1°C
Standard +100 to +140°C ± 0.1°C
Standard +140 to +150°C ± 0.1°C
High 0 to +400°C ± 0.5°C
Sensor capacity 1 or 2 1 or 2
Sensor response time:    
T-10% – / 0.11 sec. / 0.22 sec.  –
T-50% – / 0.35 sec. / 0.72 sec.  –
T-63% 0.46 sec. / 0.41 sec. / 1.00 sec.  1.46 sec. / 6.96 sec.
T-90% 0.67 sec. / 0.81 sec. / 2.00 sec.  2.87 sec. / 17.72 sec.
Pressure operating range 0.001 mBar to 4 Bar ABS  0.001 mBar to 4 Bar ABS 

Technical Specifications for Flexible sensors

 
Type Flexible Low Flexible Standard
Diameter 1.2 mm 1.8 mm
Length 100 – 500 mm 100 – 1000 mm
Dimension of sensing element  0.8 x 3 mm  1.2 x 1.6 mm
Position of measuring point:    
From round tip 3 mm 3 mm
Temperature measuring range  -196°C to +100°C*  -196°C to +140°C
Accuracy:    
Low -196 to -80°C ± 0.5°C ± 0.5°C
Low -80 to -50°C ± 0.3°C ± 0.3°C
Low -50 to -40°C ± 0.2°C ± 0.2°C
Low -40 to -25°C ± 0.1°C ± 0.1°C
Low -25 to 0°C ± 0.1°C ± 0.1°C
Standard 0 to 100°C ± 0.1°C ± 0.1°C
Standard +100 to +140°C ± 0.1°C
Standard +140 to +150°C
High 0 to +400°C
Sensor capacity 1, 2 or 4 1 or 2
Sensor response time:    
T-10%  –  –
T-50%  –  –
T-63%  1.34 sec.  2.16 sec.
T-90%  2.55 sec.  4.31 sec.
Pressure operating range 0.001 mBar to 1 Bar ABS  0.001 mBar to 4 Bar ABS 
*Can be sterilized at 125°C
 

TSP Pressure Sensors

 
  Pressure Sensor
Material 316L Stainless Steel
Measuring Principal Strain Gauge
Operating Temperature 0 to +150°C
Operating Pressure 10 mBar to 10 Bar Absolute
Measuring Range 10 mBar to 6 Bar Absolute, Up To 7 Bar Can Be Ordered         
Resolution 1 mbar
Measuring Accuracy ±0.25% Full Scale
 

TSP Combined Pressure / Temperature

 
  General Sensor Specifications
Material 316L Stainless Steel
Operating Temperature      0 to +150°C
Sampling 1 Sec. To 24 Hours Auto Start/Stop                                                
 
  Pressure Sensor
Measuring Principal        Strain Gauge
Operating Pressure 10 mBar to 10 Bar Absolute
Measuring Range 10 mBar to 6 Bar Absolute, Up To 7 Bar Can Be Ordered       
Resolution 1 mbar
Measuring Accuracy ±0.25% Full Scale
 
  Temperature Sensor                                                                
Measuring Principal External PT1000                                                                             
Length Of Sensing Element 20 mm
Measuring Range 0 to +150°C
Resolution 0.012°C
Measuring Accuracy ±0.05°C
 

Relative Humidity Sensors

 
 

1. Stability Chambers*

2. EtO/Stability

3. EtO

RH Sensing Element:

Capacitance

Capacitance

Capacitance

Temperature Sensing Element:

Chip RTD

PT1000

PT1000

 

 

   
Relative Humidity:      

Range (-40 to +80°C):

0-100%

0-95%

0-100%

Resolution:

0.10%

0.10%

0.10%

Response Time
(63% In Slowly Moving Air):

8 Sec.

6 Sec.

50 Sec.

Accuracy At 25°C Non-Condensing:
     

(10% to 90%):

±2%

±2%

±2%

 

 

   
Temperature:      
Range:

0 to +90 °C

0 to +90 °C

0 to +90 °C

Resolution:

0.01°C

0.01°C

0.01°C

Response Time:

Max 30 Sec.

 Max 5 Sec.

Max 30 Sec.

Accuracy:      

+5°C to +40°C

±0.5°C

±0.1 oC

±0.1°C

+40°C to +65°C

±1.0°C

±0.1 oC

±0.1°C

+65°C to +90°C

±1.5°C

±0.1 oC

±0.1°C

* Requires ValSuite 2.4 or newer
 

Conductivity Sensor

 
Conductivity range:  

0 to 200 μS/cm or 200 to 2000 μS/cm

Resolution: 0.1 μS/cm

Accuracy:

± 1 μS/cm or ± 2.5 % of reading whichever is worse
Temperature Range: 0°C to 100°C *
Accuracy: ± 0.05°C

Contact Material:

Peek (FDA compliant)

IP Class:

IP67

Temperature Sensor:

Pt-1000 to provide automatic temperature compensation
Dimensions L x D:  37 mm x 25 mm / 13 mm
Immersion Depth: Minimum 25 mm
*The Conductivity sensor is not designed for steam sterilization, but can be autoclaved at 121°C.

 

Software:

Desktop_metrostyle_small

E-Val PRO 2015-2a

  • New Metro style Desktop with pdf reports
  • SQL Server Express 2012, Database
  • New Report layout
  • Easy operation – Repeat function

Detailed Control of Validation Studies
The ValSuite™ software documents and guides you through the complete thermal validation process. The database structure in the software enables complete documentation and procedural control for the operators.

Graf_str
Test Setup
Templates allow detailed test criteria to be pre-set in the software by the assigned administrator. Information on sensor placement, operator, test,vessel, required temperature limits, start and stop time, monitoring interval and specific calculations can all be pre-set and saved. This ensures accurate documentation and correct implementation of required procedures for consistently repeated tests.

Pre-identifying sensor positions greatly reduces setup time and errors. A test setup sheet is an indication where each sensor should be placed. Later during analysis this information is easily displayed and tracked.

Software Data Analysis Features
Data analysis tools greatly reduce the time needed to find critical data. The ability to zoom graphically and display up to 8 tiled windows at once simplifies identifying important data. Multiple calculations such as min/max values, standard deviation, average, deltaT and lethality can be calculated on any block of data displayed.  This eliminates the need to export data which improves data security.

ValSuite™ collects and presents validation data from both real-time E-Val Flex and TrackSense® Pro wireless data logging systems. The data from both systems can be presented and analyzed in the same session. The system can run up to 128 channels which can be identified and displayed in different groups such as penetration and distribution. Any grouping or specific channels can be displayed in a separate data block and analyzed.

 

Outputting Reports
A complete thermal validation report can be produced with pass/fail criteria, detail on mapping positions, operator and vessel ID, calibration offsets for sensors, full data lists and statistical summaries on the data. ValSuite™ also maintains templates for reports designed to meet specific requirements of tests such as EN17665 (EN554). The templates can be customized to organize the data and perform calculations to your exact criteria. Offering this greatly reduces the time needed for the data analysis process. Reports can be reviewed with the print preview feature and a pdf file document is generated.

 

Maintain Security
ValSuite™ Pro operating software is designed to maintain the highest level of security for compliance with 21 CFR Part 11. The software administrator controls and assigns user ID and access privileges. Any user function can be deactivated which will deny access for specified users. This significantly reduces the risk of mistakes applies tight control of usage by the administrator.

Raw data cannot be changed and user actions are recorded in the audit trail. Any analysis of data such as time markers, limits or comments will be recorded in the audit trail. Analysis reports can be produced with an electronic signature with the ID of the user generating the report. Accessing information from the audit trail is simplified with the ability to search by date, study ID, user ID and vessel ID.

Compliant to FDA Guidelines

  • Raw data is built into a database structure and cannot be modified or erased
  • Complete audit trail with easy search engine to find data by date, session, user and module
  • User ID and passwords with detailed user access control
  • Sensor ID provides complete NIST traceability
  • Customized report generator eliminating need to export data
  • Specific compliance reports (e.g. EN17665)
  • Automated pre and post calibration reports
  • Print preview feature with report output in pdf file format
    GAMP Guidelines and DS/EN ISO 9001
    All documentation for the development of ValSuite™ Pro software is in accordance with the guidelines set out in GAMP. Software package includes appropriate documentation. Ellab’s quality system is compliant with DS/EN ISO 9001.
 ungdung-logger
Fitting-01